Image | MFG. Part # | Description | MFG. | On Hand | Price From |
|
P3-550E |
Productivity3000 CPU, up to 50 MB ladder memory, 4 x 10 character LCD display, USB A storage, (2) Ethernet 10/100Base-T (RJ45), (1) RS-232 (RJ12), (1) RS-485 (3-pin terminal) and (1) USB A expansion port(s), battery included. |
|
- |
|
|
P3-550 |
Productivity3000 CPU, up to 50 MB ladder memory, 4 x 10 character LCD display, USB A storage, (2) Ethernet 10/100Base-T (RJ45), (1) RS-232 (RJ12), (1) RS-485 (3-pin terminal), (1) USB A expansion and (1) USB B port(s), battery included. |
|
- |
|
|
P3-530 |
Productivity3000 CPU, up to 25 MB ladder memory, USB A storage, (1) Ethernet 10/100Base-T (RJ45), (1) RS-232 (RJ12), (1) RS-485 (3-pin terminal) and (1) USB A expansion port(s), battery included. |
|
- |
|
|
P3-RS |
Productivity3000 remote I/O communication module, 5 ports, (1) Ethernet (RJ45), (1) RS-232 (RJ12), (1) RS-485 (3-pin terminal), (1) USB A and (1) USB B port(s), 4 x 10 character LCD display. |
|
- |
|
|
P3-RX |
Productivity3000 remote I/O communication module, 4 ports, (1) Ethernet (RJ45), (1) RS-232 (RJ12), (1) RS-485 (3-pin terminal) and (1) USB A port(s). |
|
- |
|
|
P3-EX |
Productivity3000 local I/O expansion module, 2 ports, (1) USB A and (1) USB B port(s). |
|
- |
|
|
P3-03B |
Productivity3000 I/O base, 3-slot, DIN rail or flush mount. Requires P3-01AC or P3-01DC power supply. Holds power supply, CPU and (3) I/O modules. |
|
- |
|
|
P3-05B |
Productivity3000 I/O base, 5-slot, DIN rail or flush mount. Requires P3-01AC or P3-01DC power supply. Holds power supply, CPU and (5) I/O modules. |
|
- |
|
|
P3-08B |
Productivity3000 I/O base, 8-slot, DIN rail or flush mount. Requires P3-01AC or P3-01DC power supply. Holds power supply, CPU and (8) I/O modules. |
|
- |
|
|
P3-11B |
Productivity3000 I/O base, 11-slot, DIN rail or flush mount. Requires P3-01AC or P3-01DC power supply. Holds power supply, CPU and (11) I/O modules. |
|
- |
|
|
P3-01AC |
Productivity3000 AC base power supply, 100-240 VAC nominal input. (1) power supply required per base. |
|
- |
|
|
P3-01DC |
Productivity3000 DC base power supply, 24-48 VDC nominal input. (1) power supply required per base. |
|
- |
|
|
P3-08ND3S |
Productivity3000 discrete input module, 8-point, 12-24 VDC, sinking/sourcing, 8 isolated common(s), 1 point(s) per common. Requires P3-RTB removable terminal block or ZIPLink pre-wired cables. |
|
- |
|
|
P3-16ND3 |
Productivity3000 discrete input module, 16-point, 12-24 VDC, sinking/sourcing, 4 isolated common(s), 4 point(s) per common. Requires P3-RTB removable terminal block or ZIPLink pre-wired cables. |
|
- |
|
|
P3-32ND3 |
Productivity3000 discrete input module, 32-point, 24 VDC, sinking/sourcing, 4 isolated common(s), 8 point(s) per common. Requires ZIPLink connector modules and pre-wired cables. |
|
- |
|
|
P3-64ND3 |
Productivity3000 discrete input module, 64-point, 24 VDC, sinking/sourcing, 8 isolated common(s), 8 point(s) per common. Requires ZIPLink connector modules and pre-wired cables. |
|
- |
|
|
P3-08TD1S |
Productivity3000 discrete output module, 8-point, 6-24 VDC, sinking, 4 isolated common(s), 2 point(s) per common, 2A/point, 4A/common. Requires P3-RTB removable terminal block or ZIPLink pre-wired cables. |
|
- |
|
|
P3-08TD2S |
Productivity3000 discrete output module, 8-point, 6-24 VDC, sourcing, 4 isolated common(s), 2 point(s) per common, 2A/point, 4A/common. Requires P3-RTB removable terminal block or ZIPLink pre-wired cables. |
|
- |
|
|
P3-16TD1 |
Productivity3000 discrete output module, 16-point, 6-24 VDC, sinking, 2 isolated common(s), 8 point(s) per common, 0.5A/point, 4A/common. Requires P3-RTB removable terminal block or ZIPLink pre-wired cables. |
|
- |
|
|
P3-16TD2 |
Productivity3000 discrete output module, 16-point, 6-24 VDC, sourcing, 2 isolated common(s), 8 point(s) per common, 0.5A/point, 4A/common. Requires P3-RTB removable terminal block or ZIPLink pre-wired cables. |
|
- |
|
|
P3-16TD3P |
Productivity3000 discrete output module, 16-point, 12-24 VDC, sinking and sourcing, 4 common(s), 4 point(s) per common, 0.5A/point, 4A/common, short circuit and overload protection. Requires ZIPLink connector modules and pre-wired cables. |
|
- |
|
|
P3-32TD1 |
Productivity3000 discrete output module, 32-point, 6-24 VDC, sinking, 4 isolated common(s), 8 point(s) per common, 0.3A/point, 2.4A/common. Requires ZIPLink connector modules and pre-wired cables. |
|
- |
|
|
P3-32TD2 |
Productivity3000 discrete output module, 32-point, 24 VDC, sourcing, 4 isolated common(s), 8 point(s) per common, 0.2A/point, 1.6A/common. Requires ZIPLink connector modules and pre-wired cables. |
|
- |
|
|
P3-64TD1 |
Productivity3000 discrete output module, 64-point, 6-24 VDC, sinking, 8 isolated common(s), 8 point(s) per common, 0.1A/point, 0.8A/common. Requires ZIPLink connector modules and pre-wired cables. |
|
- |
|
|
P3-64TD2 |
Productivity3000 discrete output module, 64-point, 24 VDC, sourcing, 8 isolated common(s), 8 point(s) per common, 0.1A/point, 0.8A/common. Requires ZIPLink connector modules and pre-wired cables. |
|
- |
|
|
P3-08NAS |
Productivity3000 discrete input module, 8-point, 120-240 VAC, 8 isolated common(s), 1 point(s) per common. Requires P3-RTB removable terminal block or ZIPLink pre-wired cables. |
|
- |
|
|
P3-16NA |
Productivity3000 discrete input module, 16-point, 120-240 VAC, 4 isolated common(s), 4 point(s) per common. Requires P3-RTB removable terminal block or ZIPLink pre-wired cables. |
|
- |
|
|
P3-08TAS |
Productivity3000 discrete output module, 8-point, 120-240 VAC, 8 common(s), 8 isolated common(s), 1 point(s) per common, 1A @ 40 deg C, 0.7A @ 60 deg C. Requires P3-RTB removable terminal block or ZIPLink pre-wired cables. |
|
- |
|
|
P3-16TA |
Productivity3000 discrete output module, 16-point, 120-240 VAC, 2 isolated common(s), 8 point(s) per common, 0.5A/point, 4A/common. Requires P3-RTB removable terminal block or ZIPLink pre-wired cables. |
|
- |
|
|
P3-08TRS |
Productivity3000 relay output module, 8-point, 6-24 VDC/6-240 VAC, (8) Form A, 8 isolated common(s), 1 point(s) per common, 1.75A/point. Requires P3-RTB removable terminal block or ZIPLink pre-wired cables. |
|
- |
|